Cell Count Normalization Kit

Item # Unit Size
C544-02
200 tests
C544-10
1,000 tests

For Research Use Only Products

∼ Features ∼
- Enhance reliability of data on plate assay
- No need for lysis procedure
- Easily determine cell number just by adding the reagent

For information about measuring cell senescence via plate reader, Click Here for the product page.
For information about measuring glucose levels, Click Here for the product page.

Storage Condition: Store at 0-5oC and protect from light.

Kit Contents:
200 tests(C544-02) 1000 tests(C544-10)
Staining Solution 50 µL x 1 250 µL x 1
Dilution Buffer 10 mL x 4 100 mL x 2
Quenching Buffer 10 mL x 2 100 mL x 1
Product Manual (C544)
Protocol for Combined Analysis (SG05 and C544)


Product Description

Cell Count Normalization Kit employs a nucleic acid staining dye, Hoechst 33342 which binds to nuclear DNA to emit blue fluorescence. By measuring this blue fluorescence, correction of the measured value can easily be carried out in simple steps whereas the visual cell counting method requires cumbersome procedure. Moreover, unlike the correction by protein or ATP amount, the kit requires no lysis procedure. In addition, Quenching Buffer included in the kit enables a direct measuring of fluorescence signal without any background.



Necessity of normalization

When cells are analyzed in a microplate, the results obtained may sometimes differ depending on the number of cells per well. In such cases, normalization of the measured values will be necessary.



Comparison with conventional method

Normalization of the measured values at the time of plate assay is done by using the cell number or nucleus/protein level as an indicator. Among these detection techniques, our nuclear staining kit is easy-to-use and capable of analyzing multiple specimens.

*1 In experiment the number of nuclei varies, it may differ from the actual cell number.

*2 In experiment protein level fluctuates, it may be different from the actual cell number.


High correlation with cell number

When you are performing a plate assay the data needs to be normalized. In order to normalize the data, an assessment method equivalent (i.e. cell counting) is essential. In the experiments below, changes in fluorescence intensity were confirmed by cell number-dependents. Data at the time of plate assay were normalized by using this kit and the cell counting method. A comparison was then made between the two methods.




Cell number-dependent changes in fluorescence intensity

Cell number-dependent changes in fluorescence intensity were observed, and the results were highly linear.


HeLa cells were serially diluted and seeded in a 96-well microplate. After incubation overnight, fluorescence intensity was measured using this kit.


Comparison with cell counting method

When normalization occurred at the time of the plate assay (lactate measurement), this kit showed equivalent results to cell counting.


2-Deoxy-D-glucose was added to HeLa cells. Lactate levels in the supernatant were quantified using the Lactate Assay Kit-WST (Item#: L256)